LOMANCO Ventilation Turbines
The possibilities of usage of Lomanco ventilation turbines:
- Ventilation of the roof-coat
- Ventilation of interiors - garret expanses, utilitarian halls, rooms
- Ventilation of block of flats - replacement of central electric ventilators
Why ventilate with Lomanco ?
Enemies are HEAT and MOISTURE - Evident in all geographical areas Year round
-
Heat
Unventilated attics often are 50-60 degrees Celsius. ----> Damages shingles, roof sheathing and radiates into living area.
-
Moisture
Moisture is the Nr.1 enemy. ----> Causes rot, mildew, mold, paint blisters, ineffective insulation.
-
Mold Facts
Attics, crawl spaces, and basements are prime sources for excess moisture.
Spores need a food source, heat, and moisture to begin colonizing.
Usually improper intake is the culprit in moisture related problems in attics.
Extreme caution should be exercised if an odor or colony is detected.
LOMANCO coloured turbines brown, black and white = harmonized roof Lomanco
All turbines available with coloured base and adjustable throat for pitched roofs.
Ventilated roof by LOMANCO air circulation
The blast of difference between the indoor and outdoor temperature, which effects the roofs during summer but mainly during the winter, must be handled good designed and then good realized roof. The design of composition and construction of the roof is from technical point of view affected e.g. by the bevel of the roof, by termoisolation and hydroisolation properties of the layers and of the whole construction. Especially important are the release of heat and steam, the order of layers in construction, and particularly the temperature and partial pressure of the heat and steam in the environment; and the effectiveness of roof ventilations.
The basic function of ventilating airspace between the termoisolation and safety foil is to lead the moisture off from the fibre of roof coat. The fluctuating air takes with the moisture held in termoisolation and leads it off out of the roof construction.
By latterly we have been using only passive ways of ventilation - ridge ventilating girdles, ventilating tiles, little shafts etc. Lomanco manufactures the program of active ventilation by the means of ventilation turbine. One Lomanco ventilation turbine can replace several passive ventilating components of the roof coat. Ventilation by the means of ventilation turbine Lomanco ensures by its active motion even wash down of the roof coat, which reduces the temperature of the coat during the summer and prevents the damage by agglomeration, bulge, pluck down etc. During the winter the fluent air wash down of roof coat ensures its even temperature and prevents the coat from creation of ice dams what means uneven extreme loading of the roof by ice and snow. During both seasons it assures fluent moisture exhaust from the roof coat and this way it prevents the creation of putrescence and mildew, which shorten the persistence of the roof.
Ventilation turbine LOMANCO - serie BIB
- Approved for all tile and slate roof constructions.
- Permanently lubricated upper and lower ball bearings that ensure long life and no maintenance.
- All-aluminum rust-free construction.
- Rigid spider-type structure.
- Riveted at every connection.
- 21 air-foil curved vanes with rolled vane edges to deflect water.
- Exclusive vari-pitch base adjusts to roof pitch.
- Large flashing for easy installation.
- Tested to withstand winds of 147 m.p.h.
- 15 years guarantee - residential.
- Easy installation.
Technical design of LOMANCO ventilation turbines:
Description of Lomanco ventilation turbines and its bearings (.pdf)
| Attic Floor Space Ventilated Area/ Turbines Needed (pcs) | |||
|---|---|---|---|
| Roof Area to Be ventilated | IB 8 | BIB 12 | BIB 14 |
| 0 - 90 m2 | 3 | 2 | 2 |
| 90 - 140 m2 | 6 | 2 | 2 |
| 140 - 185 m2 | 9 | 3 | 2 |
| 185 - 230 m2 | 12 | 4 | 3 |
| 230 - 275 m2 | 12 | 4 | 3 |
| Min. Area of Intake Vents (cm2/pc) | |||
|---|---|---|---|
| Roof Area to Be Ventilated | IB 8 | BIB 12 | BIB 14 |
| 0 - 90 m2 | 1006 | 1508 | 1508 |
| 90 - 140 m2 | 782 | 2346 | 2346 |
| 140 - 185 m2 | 689 | 2067 | 3100 |
| 185 - 230 m2 | 642 | 1927 | 2570 |
| 230 - 275 m2 | 768 | 2305 | 3072 |
Above mentioned performance values were measured in the up-to-date aerodynamic tunnel at LOMANCO under the circumstances simulating real utilization. Tests were performanced according to the latest science knowledge. Independent Ryan Engineering (Arcansas) checked the methodology. Lomanco has been permanently checking their efficiency and compare it with the competition turbines. And that is the reason why they keep their strong position in the world.
| LOMANCO Ventilation Turbines - Description | |||
|---|---|---|---|
| Material | Diameter | Colour | Type Marking |
| Aluminum | 203 mm | Eloxal Al, mill finish | IB 8 (head only) |
| Galva | 305 mm | Natural FeZn | GT 12 (base+throat+head) |
| Aluminum | 305 mm | Eloxal Al, colour coated | BIB 12, BIB 12 c (base+throat+head) |
| Aluminum | 356 mm | Eloxal Al, colour coated | BIB 14, BIB 14 c (base+throat+head) |
| Aluminum | 305 mm | Eloxal Al, colour coated | TIB 12, TIB 12 c (head only) |
| Aluminum | 356 mm | Eloxal Al, colour coated | TIB 14, TIB 14 c (head only) |
- Type marking TIB means head only
- Type marking BIB means complete product (head, adjustable throat and base for the flat roofings)